Cascade units for neon isotopes production by rectification method
Завантаження...
Дата
Назва журналу
Номер ISSN
Назва тому
Видавець
Фізико-технічний інститут низьких температур ім. Б.І. Вєркіна НАН України
Анотація
Basics of neon separation into isotopes by distillation method at T = 28 K are discussed. The required numbers
of transfer units of the top and bottom column sections at different loads are calculated. The experimental
characteristics of packed rectification columns are presented and examples of the cascade outlined. A scheme of
cryogenic circuit based on the high-pressure throttle neon cycle with intermediate nitrogen cooling is presented.
The necessity and the technical ability to create the driving difference of pressures between columns of various
stages demonstrated.
Опис
Теми
9th International Conference on Cryocrystals and Quantum Crystals
Цитування
Cascade units for neon isotopes production
by rectification method / V.L. Bondarenko, Yu.M. Simonenko, O.V. Diachenko, E.V. Matveyev // Физика низких температур. — 2013. — Т. 39, № 5. — С. 617–622. — Бібліогр.: 9 назв. — англ.