Modernization of commutation devices and an improvement of main parameters of the UTR-2 radio telescope
Завантаження...
Дата
Назва журналу
Номер ISSN
Назва тому
Видавець
Головна астрономічна обсерваторія НАН України
Анотація
The paper describes the results of modernization of the calibration system commutation devices and a check of pattern parameters of the UTR-2 radio telescope. As a result of the modernization an effective area of the telescope has been increased by 23 percent. In a frequency range from 20 to 32 MHz an improvement in sensitivity more than 1.2...1.5 dB has been obtained. On the lower end of the UTR-2 operating frequency range (from 8 to 12 MHz) the interference immunity has been increased by 10 dB.
Опис
Теми
MS1: Decameter Radioastronomy
Цитування
Modernization of commutation devices and an improvement of main parameters of the UTR-2 radio telescope / V.V. Zakharenko, N.K. Sharykin, E.R. Rudavin // Кинематика и физика небесных тел. — 2005. — Т. 21, № 5-додаток. — С. 90-92. — Бібліогр.: 3 назв. — англ.