The study of the oxide coating effect on bone–implant interface formation by means of electron microscopy method with energy dispersive x-ray analysis

dc.contributor.authorGudakova, A.A.
dc.contributor.authorDanilchenko, S.N.
dc.contributor.authorSukhodub, L.F.
dc.contributor.authorLuk'yanchenko, V.V.
dc.contributor.authorZykova, A.V.
dc.contributor.authorSafonov, V.I.
dc.date.accessioned2017-01-04T20:10:09Z
dc.date.available2017-01-04T20:10:09Z
dc.date.issued2007
dc.description.abstractThe experimental results of the measurement of the tissue constituent elements distribution, as well as impurity elements in the tissues around a Ti-implant with protective TiO₂ oxide coating are presented. Study of morphology, qualitative and quantitative analysis were carried out by means of scanning electron microscopy method with energy dispersive X-ray analysis. The results show weak migration of Ti into the bone tissue near the interface and protective role of the oxide coatings.uk_UA
dc.description.abstractПредставлено експериментальні результати дослідження розподілу елементів, що входять до складу кісткової тканини та слідів елементів у тканинах навколо титанового імплантату з захисним покриттям ТiO₂. Дослідження морфології, кількісний та якісний аналіз проводили за допомогою методу скануючої електронної мікроскопії з рентгенівським мікроаналізом. Результати показали слабку міграцію титану в кісткову тканину біля інтерфейсу та біосумісність оксидних покриттів.uk_UA
dc.description.abstractПредставлены экспериментальные результаты исследования распределения элементов, составляющих костную ткань и примесей элементов в тканях вокруг титанового имплантата с защитным покрытием ТiO₂. Изучение морфологии, количественный и качественный анализ проводили с помощью метода сканирующей электронной микроскопии с рентгеновским микроанализом. Результаты показали слабую миграцию титана в костную ткань возле интерфейса и биосовместимость оксидных покрытий.uk_UA
dc.description.sponsorshipWe thank T.G. Kalinichenko and P.A. Pavlenko for electron microscopy and X-ray microanalysis.uk_UA
dc.identifier.citationThe study of the oxide coating effect on bone–implant interface formation by means of electron microscopy method with energy dispersive x-ray analysis / A.A. Gudakova, S.N. Danilchenko, L.F. Sukhodub, V.V. Luk'yanchenko, A.V. Zykova, V.I. Safonov // Вопросы атомной науки и техники. — 2007. — № 1. — С. 145-147. — Бібліогр.: 7 назв. — англ.uk_UA
dc.identifier.issn1562-6016
dc.identifier.otherPACS: 87.68.+z
dc.identifier.urihttps://nasplib.isofts.kiev.ua/handle/123456789/110583
dc.language.isoenuk_UA
dc.publisherНаціональний науковий центр «Харківський фізико-технічний інститут» НАН Україниuk_UA
dc.relation.ispartofВопросы атомной науки и техники
dc.statuspublished earlieruk_UA
dc.subjectLow temperature plasma and plasma technologiesuk_UA
dc.titleThe study of the oxide coating effect on bone–implant interface formation by means of electron microscopy method with energy dispersive x-ray analysisuk_UA
dc.title.alternativeДослідження впливу оксидного покриття на формування інтерфейсу кість-імплантат методом скануючої електронної мікроскопії з рентгеноспектральним мікроаналізаторомuk_UA
dc.title.alternativeИсследование влияния оксидного покрытия на формирование интерфейса кость-имплант методом сканирующей электронной микроскопии с рентгеноспектральным микроанализаторомuk_UA
dc.typeArticleuk_UA

Файли

Оригінальний контейнер

Зараз показуємо 1 - 1 з 1
Завантаження...
Ескіз
Назва:
48-Gudakova.pdf
Розмір:
241.74 KB
Формат:
Adobe Portable Document Format

Контейнер ліцензії

Зараз показуємо 1 - 1 з 1
Завантаження...
Ескіз
Назва:
license.txt
Розмір:
817 B
Формат:
Item-specific license agreed upon to submission
Опис: