Influence of main beam parameters stability on beam size measurements at PITZ

dc.contributor.authorSpesyvtsev, R.
dc.date.accessioned2017-01-04T20:13:58Z
dc.date.available2017-01-04T20:13:58Z
dc.date.issued2007
dc.description.abstractThe photo injector test facility in Zeuthen (PITZ) is used to develop and characterize electron sources which produce a nominal bunch charge of 1 nC with the lowest possible transverse emittance. Measurements of the beam size provide us with knowledge on important beam characteristics. For example the measurement of the emittance is based on beam size measurements. Therefore, the control of uncertainties of beam size measurements is very important to validate the experimental results. The statistical uncertainty of transverse beam size measurements due to the beam energy and bunch charge jitters is considered in this paper.uk_UA
dc.description.abstractСтенд випробувань фотоінжекторів PITZ використовується для розробки та вивчення характеристик джерел електронів, що випромінюють пучки з номінальним зарядом в 1 нКл та якомога меншим емітансом. Одним з базових вимірів є вимір поперечного розміру електронного пучка. Наприклад вимірювання емітансу базується на вимірах розміру пучка. Таким чином врахування невизначеності вимірів розміру пучка є важливим для визначення вірогідності експериментальних результатів. В даній роботі розглянута статистична невизначеність виміру поперечного розміру електронного пучка в PITZ.uk_UA
dc.description.abstractСтенд испытания фотоинжекторов PITZ служит для разработки и характеризации источников электронов, которые способны производить пучки с номинальным зарядом в 1 нКл и малым поперечным эмиттансом. Одним из базисных измерений при характеризации фотоинжектора является измерение поперечного размера электронного пучка. В частности, измерение поперечного эмиттанса основано на измерениях размера пучка. Знание погрешности в измерении размера пучка является очень важным условием для определения достоверности экспериментальных результатов. В данной работе рассмотрена статистическая неопределенность в измерении поперечного размера электронного пучка, вызванная флуктуациями энергии и заряда пучка.uk_UA
dc.description.sponsorshipThis work has partly been supported by the European Community, contract numbers RII3-CT-2004-506008 (IA-SFS) and 011935 (EURO-FEL), and by the ”Impuls- und Vernetzungsfonds” of the Helmholtz Association, contract number VH-FZ-005. The author would like to thank all members of the PITZ group and especially S. Khodyachykh, L. Staykov and M. Krasilnikov for the productive discussions and helpful advices.uk_UA
dc.identifier.citationInfluence of main beam parameters stability on beam size measurements at PITZ / R. Spesyvtsev // Вопросы атомной науки и техники. — 2007. — № 5. — С. 200-203. — Бібліогр.: 9 назв. — англ.uk_UA
dc.identifier.issn1562-6016
dc.identifier.otherPACS: 03.65.Pm, 03.65.Ge, 61.80.Mk
dc.identifier.urihttps://nasplib.isofts.kiev.ua/handle/123456789/110585
dc.language.isoenuk_UA
dc.publisherНімецький Електронний-Синхротрон (DESY) Німеччиниuk_UA
dc.relation.ispartofВопросы атомной науки и техники
dc.statuspublished earlieruk_UA
dc.subjectТеория и техника ускорения частицuk_UA
dc.titleInfluence of main beam parameters stability on beam size measurements at PITZuk_UA
dc.title.alternativeВплив стабільності основних параметрів пучка на вимір розміру пучка в PITZuk_UA
dc.title.alternativeВлияние стабильности основных параметров пучка на измерение размера пучка в PITZuk_UA
dc.typeArticleuk_UA

Файли

Оригінальний контейнер

Зараз показуємо 1 - 1 з 1
Завантаження...
Ескіз
Назва:
200-Spesyvtsev.pdf
Розмір:
375.63 KB
Формат:
Adobe Portable Document Format
Опис:
Стаття

Контейнер ліцензії

Зараз показуємо 1 - 1 з 1
Завантаження...
Ескіз
Назва:
license.txt
Розмір:
817 B
Формат:
Item-specific license agreed upon to submission
Опис: