Influence of Solution pH on Stability of Fumed Silica–Polyacrylic Acid Systems

dc.contributor.authorWiśniewska, M.
dc.contributor.authorTerpiłowski, K.
dc.contributor.authorZarko, V.I.
dc.contributor.authorChibowski, S.
dc.contributor.authorChibowski, E.
dc.contributor.authorUrban, T.
dc.contributor.authorGun’ko, V.M.
dc.date.accessioned2011-11-27T16:49:31Z
dc.date.available2011-11-27T16:49:31Z
dc.date.issued2010
dc.description.abstractThe influence of polyacrlic acid (PAA) adsorption on fumed silica (SiO2) surface on suspension stability has been studied. Сhanges in the suspension stability were monitored using a Turbiscan LabExpert with a TLAb Cooler cooling module at 25oC. PAA is an anionic polymer containing carboxyl groups; therefore all the measurements were carried out at different pH 3, 6 and 9. Analysis of obtained transmission and backscattering curves and Turbiscan Stability Indexes (TSI) allowed determination of the most probable mechanism of the system stability.uk_UA
dc.description.abstractВивчено вплив адсорбції поліакрилової кислоти (ПAК) на поверхні високодисперсного кремнезему (SiO2) на стабільність суспензії. Зміни стабільності суспензії спостерігались за допомогою приладу Turbiscan LabExpert із охолоджуючим модулем TLAb Cooler при 25oC. ПAК є аніонним полімером, що містить карбоксильні групи, тому всі вимірювання проводились при різних рН (3, 6 та 9). Аналіз одержаних кривих перенесення та зворотнього розсіяння, а також індексів стабільності (Turbiscan Stability Indexes (TSI)) дозволив визначити найбільш вірогідний механізм стабілізації вивчених систем.uk_UA
dc.description.abstractИзучено влияние адсорбции полиакриловой кислоты (ПAA) на поверхности высокодисперсного кремнезема (SiO2) на стабильность суспензии. Изменения стабильности суспензии наблюдались с помощью прибора Turbiscan LabExpert с охлаждающим модулем TLAb Cooler при 25oC. PAA является анионным полимером, содержащим карбоксильные группы, поэтому все измерения проводились при различных рН (3, 6 и 9). Анализ полученных кривых переноса и обратного рассеяния, а также индексов стабильности (Turbiscan Stability Indexes (TSI)) позволил определить наиболее вероятный механизм стабилизации изученных систем.uk_UA
dc.description.sponsorshipThe research leading to these results has received funding from the European Community’s Seven Framework Programme (FP7/2007 – 2013) under a Maria Curie International Research Staff Exchange Scheme, Grant Agreement No. PIRSES – GA – 2008 – 230790.
dc.identifier.citationInfluence of Solution pH on Stability of Fumed Silica–Polyacrylic Acid Systems / M. Wiśniewska, K. Terpiłowski, V.I. Zarko, S. Chibowski, E. Chibowski, T. Urban, V.M. Gun’ko // Хімія, фізика та технологія поверхні. — 2010. — Т. 1, № 3. — С. 269-273. — Бібліогр.: 6 назв. — англ.uk_UA
dc.identifier.issn2079-1704
dc.identifier.udc544.723
dc.identifier.urihttps://nasplib.isofts.kiev.ua/handle/123456789/28991
dc.language.isoenuk_UA
dc.publisherІнститут хімії поверхні ім. О.О. Чуйка НАН Україниuk_UA
dc.relation.ispartofХімія, фізика та технологія поверхні
dc.statuspublished earlieruk_UA
dc.subjectФункціоналізовані матеріали, одержані золь-гель і темплатним методамиuk_UA
dc.titleInfluence of Solution pH on Stability of Fumed Silica–Polyacrylic Acid Systemsuk_UA
dc.title.alternativeВплив рН розчину на стабільність систем високодисперсний кремнезем – поліакрилова кислотаuk_UA
dc.title.alternativeВлияние рН раствора на стабильность систем высокодисперсный кремнезем – полиакриловая кислотаuk_UA
dc.typeArticleuk_UA

Файли

Оригінальний контейнер

Зараз показуємо 1 - 1 з 1
Завантаження...
Ескіз
Назва:
11-Wisniewska.pdf
Розмір:
702.32 KB
Формат:
Adobe Portable Document Format

Контейнер ліцензії

Зараз показуємо 1 - 1 з 1
Завантаження...
Ескіз
Назва:
license.txt
Розмір:
929 B
Формат:
Item-specific license agreed upon to submission
Опис: