Optimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus disease

dc.contributor.authorKhrystosenko, R.V.
dc.date.accessioned2017-06-14T15:23:15Z
dc.date.available2017-06-14T15:23:15Z
dc.date.issued2016
dc.description.abstractThe influence of the sensitive element fabrication technology and noise performance of surface plasmon resonance (SPR) immunosensor on sensitivity and stability of operation inherent to the “Plasmon” series instrument has been investigated to improve reliability of diagnosis and treatment of the Epstein–Barr herpes virus disease. To minimize the effect of the temperature change induced noise, compensation (introduction of the reference channel) and stabilization (active thermal control) methods were applied, allowing to substantially enhance resolution of the used SPR sensor system.uk_UA
dc.description.sponsorshipThe author would like to thank the employees of D. Zabolotny Institute of Microbiology and Virology of NAS of Ukraine: N.V. Nesterova, S.D. Zagorodnya, G.V. Baranova, A.V. Golovan, and the employees of V. Lashkaryov Institute of Semiconductor Physics of NAS of Ukraine Yu.V. Ushenin and A.V. Samoylov for their assistance in performing this work. This work was supported by the National Academy of Sciences of Ukraine through the project “Pilot operation and metrological support diagnostic instrument based on surface plasmon resonance for the diagnosis of herpes virus. Design and manufacture of sensing elements, electronic, mechanical and software modules devices based on surface plasmon resonance”.uk_UA
dc.identifier.citationOptimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus disease / R.V. Khrystosenko // Semiconductor Physics Quantum Electronics & Optoelectronics. — 2016. — Т. 19, № 1. — С. 84-89. — Бібліогр.: 19 назв. — англ.uk_UA
dc.identifier.issn1560-8034
dc.identifier.otherDOI: 10.15407/spqeo19.01.084
dc.identifier.otherPACS 73.20.Mf, 87.55.fk
dc.identifier.urihttps://nasplib.isofts.kiev.ua/handle/123456789/121531
dc.language.isoenuk_UA
dc.publisherІнститут фізики напівпровідників імені В.Є. Лашкарьова НАН Україниuk_UA
dc.relation.ispartofSemiconductor Physics Quantum Electronics & Optoelectronics
dc.statuspublished earlieruk_UA
dc.titleOptimization of surface plasmon resonance based biosensor for clinical diagnosis of the Epstein–Barr herpes virus diseaseuk_UA
dc.typeArticleuk_UA

Файли

Оригінальний контейнер

Зараз показуємо 1 - 1 з 1
Завантаження...
Ескіз
Назва:
16-Khrystosenko.pdf
Розмір:
204.47 KB
Формат:
Adobe Portable Document Format

Контейнер ліцензії

Зараз показуємо 1 - 1 з 1
Завантаження...
Ескіз
Назва:
license.txt
Розмір:
817 B
Формат:
Item-specific license agreed upon to submission
Опис: