Position-sensitive detector based on plastic scintillator for muon tomography
dc.contributor.author | Ivanov, A.I. | |
dc.contributor.author | Tarasov, V.A. | |
dc.contributor.author | Pedash, V.Y. | |
dc.date.accessioned | 2017-06-05T18:57:04Z | |
dc.date.available | 2017-06-05T18:57:04Z | |
dc.date.issued | 2015 | |
dc.description.abstract | The analysis of the different models of a plastic position-sensitive detector construction for muon tomography is discussed. The key feature of the detectors is the ability of, a passive registration of ionizing radiation from the inspected object. The optimal configuration of the detector has been determined, and its main parameters in both modes of operation has been assesed. | uk_UA |
dc.identifier.citation | Position-sensitive detector based on plastic scintillator for muon tomography / A.I.Ivanov, V.A.Tarasov, V.Y.Pedash // Functional Materials. — 2015. — Т. 22, № 1. — С. 144-148. — Бібліогр.: 6 назв. — англ. | uk_UA |
dc.identifier.issn | 1027-5495 | |
dc.identifier.other | DOI: http://dx.doi.org/10.15407/fm22.01.144 | |
dc.identifier.uri | https://nasplib.isofts.kiev.ua/handle/123456789/119296 | |
dc.language.iso | en | uk_UA |
dc.publisher | НТК «Інститут монокристалів» НАН України | uk_UA |
dc.relation.ispartof | Functional Materials | |
dc.status | published earlier | uk_UA |
dc.subject | Devices and instruments | uk_UA |
dc.title | Position-sensitive detector based on plastic scintillator for muon tomography | uk_UA |
dc.type | Article | uk_UA |