Empirical formula for the dependence of HPGe-detector efficiency on energy and distance for shielded gamma-ray sources

dc.contributor.authorPylypchynets, I.V.
dc.contributor.authorLengyel, O.I.
dc.contributor.authorParlag, O.O.
dc.contributor.authorOleynikov, E.V.
dc.date.accessioned2023-12-10T16:49:35Z
dc.date.available2023-12-10T16:49:35Z
dc.date.issued2023
dc.description.abstractThe accuracy of gamma-spectrometric measurements in the isotopic analysis of shielded nuclear materials depends on the accuracy of the detector calibration in terms of energy efficiency, which should take into account corrections related to the measurement geometry and the absorption of γ-radiation by the shield material. The results of experimental studies of the energy efficiency of the HPGe-detector measured at fixed distances between the calibration source and the detector (50 and 100 mm) in the presence and absence of an absorbing shield made of stainless steel 12X18H10T (thickness ‒ 9.6 mm) are presented. On the basis of experimental data, an empirical description of the efficiency dependence for fixed distances between the gamma radiation source and the detector in the presence of a stainless steel absorbing shield was obtained.uk_UA
dc.description.abstractТочність гамма-спектрометричних вимірів при ізотопному аналізі екранованих ядерних матеріалів залежить від точності калібрування детектора за енергетичною ефективністю, що повинна враховувати поправки, пов’язані з геометрією вимірювань, та поглинанням γ-випромінювання матеріалом екрана. Представленo результати експериментальних досліджень енергетичної ефективності HPGe-детектора, яка виміряна при фіксованих відстанях калібрувальне джерело – детектор (50 і 100 мм) при наявності та відсутності поглинаючого екрану із нержавіючої сталі марки 12Х18Н10Т (товщина – 9,6 мм). На основі експериментальних даних отримано емпіричне описання залежності ефективності для фіксованих відстаней між джерелом гамма-випромінювання і детектором при наявності поглинаючого екрана із нержавіючої сталі.uk_UA
dc.description.sponsorshipThe authors express their gratitude to the microtron group of I.M. Kushtan for the technical support of the experimental studies.uk_UA
dc.identifier.citationEmpirical formula for the dependence of HPGe-detector efficiency on energy and distance for shielded gamma-ray sources / I.V. Pylypchynets, O.I. Lengyel, O.O. Parlag, E.V. Oleynikov // Problems of Atomic Science and Technology. — 2023. — № 3. — С. 47-51. — Бібліогр.: 22 назв. — англ.uk_UA
dc.identifier.issn1562-6016
dc.identifier.otherPACS: 24.75.+1, 25.85.-w, 25.85.Ec, 25.85. Ca
dc.identifier.otherDOI: https://doi.org/10.46813/2023-145-047
dc.identifier.urihttps://nasplib.isofts.kiev.ua/handle/123456789/196137
dc.language.isoenuk_UA
dc.publisherНаціональний науковий центр «Харківський фізико-технічний інститут» НАН Україниuk_UA
dc.relation.ispartofProblems of Atomic Science and Technology
dc.statuspublished earlieruk_UA
dc.subjectDetectors and nuclear radiation detectionuk_UA
dc.titleEmpirical formula for the dependence of HPGe-detector efficiency on energy and distance for shielded gamma-ray sourcesuk_UA
dc.title.alternativeЕмпірична формула залежності ефективності HPGe-детектора від енергії та відстані для екранованих джерел гамма-випромінюванняuk_UA
dc.typeArticleuk_UA

Файли

Оригінальний контейнер

Зараз показуємо 1 - 1 з 1
Завантаження...
Ескіз
Назва:
09-Pylypchynets.pdf
Розмір:
628.57 KB
Формат:
Adobe Portable Document Format

Контейнер ліцензії

Зараз показуємо 1 - 1 з 1
Завантаження...
Ескіз
Назва:
license.txt
Розмір:
817 B
Формат:
Item-specific license agreed upon to submission
Опис: